FLOOR WARMING PIPE/TANK TRACE MORE INFO     
 

 


Radiant Floor Heat Cables

LMI radiant heating systems are warming tile, stone, marble, vinyl, concrete, and hardwood floors in kitchens, bathrooms, foyers, and more every day. By installing a LMI system, these classic surfaces become as livable as they are stylish. Your (bare) feet will thank you. LMI is designed to go right in the mortar layer beneath the floor coverings. Our freeform cables can evenly warm the floor inside any room shape and are installed while remodeling or in new construction.

A LMI system can be designed to warm an otherwise cold floor covering or it can turn your entire floor surface into a giant, efficient room radiator. Either way heat is provided right at your feet where you need it most. The larger the surface, the lower the actual surface temperature required. A wall radiator may have a surface temperature of 180°F while an 85°F heated floor will produce the same result!

Heat Trace Cables - Radiant Floor Heating:
LMI’s Silicon Jacket (SJ) Floor Warming Cable is factory terminated and arrives on the job site complete and ready to install. It is flexible, easily bends to accommodate existing or planned built-ins, lays flat, and can cover the entire open floor area.
  • Constant watt output along heated length
  • Inventoried at distributorships and by manufacturer

  • Can install in 120, 208, 240, and 277 VAC
  • A single cable on one circuit can cover 280 square feet (floor warming) or 180 square feet (primary heating)
We also carry Mineral Insulated Floor Warming Cable and products for pipe and tank tracing and roof and gutter snow melt applications.
 
120 Volt Cable
Model Heating Floor Area Volts Watts Amps Cable Length
Primary Secondary
FW12-15 15 sf 20 sf 120V 218 1.8 30'
FW12-25 25 sf 40 sf 120V 372 3.1 53'
FW12-40 40 sf 55 sf 120V 456 3.8 76'
FW12-50 50 sf 75 sf 120V 612 5.1 101'
FW12-70 70 sf 105 sf 120V 924 7.7 142'
FW12-80 80 sf 120 sf 120V 1188 9.9 158'
FW12-100 100 sf 150 sf 120V 1176 9.8 197'

240 Volt Cable

Model Heating Floor Area Volts Watts Amps Cable Length
Primary Secondary
FW24-30 30 sf 45 sf 240V 432 1.8 60'
FW24-55 55 sf 84 sf 240V 720 3.1 110'
FW24-70 70 sf 110 sf 240V 960 3.8 140'
FW24-100 100 sf 150 sf 240V 1224 5.1 200'
FW24-140 140 sf 215 sf 240V 1872 7.8 280'
FW24-160 160 sf 250 sf 240V 2328 9.7 320'
FW24-170 170 sf 255 sf 240V 2184 9.1 340'
FW24-180 180 sf 270 sf 240V 2592 10.8 360'

 

Floor Warming Thermostats:

FL-1224P
120/240 Volt Electronic Floor Warming Thermostat
Thermostats with Built-in GFCI

Electronic on/off thermostat with integrated GFCI.
Ground Fault Circuit Interrupter (GFCI): The thermostat has integrated a Ground Fault Circuit Interrupter (GFCI, Class A). In case a ground fault should occur it will disconnect both lines to the heating element. The thermostat and the GFCI is a dual model suitable for 120/240V 50/60 Hz supply.

Individual programming of events:
The factory-set periods and/or temperatures can be deleted or changed according to requirement. Furthermore, the following programs can be selected:
- 4 events 6 days and 2 events day 7
- 4 events per day.
The clock thermostat is with adaptive function meaning the thermostat calculates when the heating has to be switched on to make sure that the comfort temperature is obtained at the required time.

Comfort mode:
The temperature can be temporarily changed for a single event. The comfort mode temperature is reset at the next event, and the thermostat will return to the scheduled event program.

Manual mode:
The scheduled event program can be cancelled e.g. during holidays, instead the temperature can be adjusted to e.g. 41°F (5°C) for frost protection. The new setpoint is valid until the manual mode is cancelled.

Monitoring of energy consumption:
Total switch-on time in percentage can be read-out within the latest 2 days, 30 days or 365 days. In this way the heat consumption can be controlled.

Temperature Limitation:
The UCCD is delivered with a floor sensor which can be used for:
Max. temperature limitation: Protection of e.g. wooden floors.
Min. temperature limitation: For better heating comfort.

Backup function:
In the event of a power failure, an internal circuit will maintain the programming and time. Only if the power failure exceeds 50 hours, the time will have to be reset.

It's safe
• C-UL LISTED.
• GFCI Class A, 5mA trip level.
• GFCI disconnects line and neutral (L2).

It's flexible and user-friendly
• Dual voltage 120V or 240V.
• Output relay 16A.
• Screw terminals.
• Easy switching between °F and °C.
• Inclined display for better read-out.
• Icons for easy understanding.

It's cost efficient and comfort
• built-in clock function for automatic comfort and setback temperature.
• Floor sensor.

Price $200.00.
120/240 Volt Electronic Floor Warming Thermostat

Floor Warming Accessories:

SPK-FW
Floor Warming Splice Kit
Splice Kit for one splice in Floor Warming cable.
Price $37.50.
Floor Warming Splice Kit

 

Contact Us

© 2005

  LMI Marketing, LLC

1-866-770-9416

information@heattracecables.com

terms and policies

 

SITE DESIGNED AND HOSTED BY:
SBS, Inc.